English  |  正體中文  |  简体中文  |  全文笔数/总笔数 : 43236/136804
造访人次 : 2072738      在线人数 : 147
RC Version 3.1 © Powered By DSPACE, MIT. Enhanced by NTU Library IR team.
搜寻范围 进阶搜寻

jsp.display-item.identifier=請使用永久網址來引用或連結此文件: http://ntur.lib.ntu.edu.tw/handle/246246/169033

题名: Septal Pacing Preserving Better Left Ventricular Mechanical Performance and Contractile Synchronism Than Apical Pacing in Patients Implanted with an Atrioventricular Sequential Dual Chamber Pacemaker.
心室中隔激活防止房室雙腔節律器對左心室功能之不良影響
作者: 游治節;劉言彬;林茂欣;王禎煜;林俊立;林隆君
YU, CHIH-CHIEH;LIU, YEN-BIN;LIN, MAO-SHIN;WANG, JEN-YU;LIN, JIUNN-LEE;LIN, LUNG-CHUN
贡献者: 綜合診療部
日期: 2007
上传时间: 2009-09-30T06:40:58Z
摘要: BACKGROUND: Permanent pacing is the treatment for chronotropically incompetent hearts. However, the right ventricular (RV) apical pacing- induced asynchrony, even maintaining the atrioventricular (AV) sequential activation, has depressed left ventricular contractility. Whether RV septal pacing would less compromise the electromechanical performance of the left ventricle and the chronotropic effect on myocardial contractility , is unknown. METHODS: We prospectively studied 42 patients without structural heart diseases and with symptomatic bradycardia. There were 10 patients receiving atrial pacing (AAI) pacemakers, 18 patients having AV sequential pacing at RV apex (DDDapx) and 14 patients being AV sequentially paced at septum (DDDspt). Echocardiography was performed before and within 72 h after the pacemaker implantation. The ventricular mechanical performance and asynchrony was compared in conditions of programmed rates of 60, 80 and 100/min. RESULTS: Myocardial performance index was significantly better in DDDspt than in DDDapx patients (p=0.003) . With faster programmed rate, the QRS/RR increased (p<0.05) in DDDapx patients with more inter- and intraventricular asynchrony, implicating the disadvantage of prolonged depolarization time. The DDDspt group demonstrated comparable parameters of diastolic function to AAI patients and preserved mechanical performance during accelerated pacing. CONCLUSIONS: RV septal pacing showed the advantages of shorter depolarization time, less ventricular contractile asynchrony , better mechanical performance and preserved chronotropic response on myocardial contractility in comparison with apical pacing. patients having AV sequential pacing at RV apex (DDDapx) and 14 patients being AV sequentially paced at septum (DDDspt).
關聯: INTERNATIONAL JOURNAL OF CARDIOLOGY v.118 n.1 pp.97-106
显示于类别:[附設醫院綜合診療部] 期刊論文

文件中的档案:

没有与此文件相关的档案.



在NTUR中所有的数据项都受到原著作权保护.

 

DSpace Software Copyright © 2002-2004  MIT &  Hewlett-Packard  /   Enhanced by   NTU Library IR team  - 回馈